Place of Origin: | China |
Brand Name: | Brando |
Certification: | CE |
Model Number: | US/UD-8 |
Minimum Order Quantity: | 1 set |
---|---|
Price: | negotiation |
Packaging Details: | Inner Box, Carton, Pallet |
Delivery Time: | 4-8 days |
Payment Terms: | L/C, T/T, Western Union,Paypal, MoneyGram |
Supply Ability: | 10000 sets per month |
Ref Number: | US-8, UD-8, 2W025-08 | Function: | 2/2 Normally Closed (NC) |
---|---|---|---|
Port Size: | 1/4'' Inch | Orifice Size: | 2.5mm |
Body Material: | Forged Brass | Plug Material: | FKM (Viton) |
O-ring Material: | FKM (Viton) | Voltage: | AC110V, AC220V, DC24V |
Fluid Temperature: | -5°C To +80°C | Application: | Dental Medical Equipment |
Highlight: | Brass Water Solenoid Valve,Brass Electric Solenoid Valve,Brass Liquid Solenoid Valve |
US-8 / UD-8 / 2W025-08 Brass Solenoid Valve UNI-D Type 1/4'' Inch FKM AC220V / DC24V
The show solenoid valve is US-8 / UD-8 / 2W025-08 Solenoid Valve, which is the same as UNI-D type. The port size is G1/4'' inch, the orifice size is 2.5mm, seal material is FKM (for steam).
The product description
1. The US series is a direct action, conductive and normally closed (NC) 2/2-way solenoid valve.
2. Direct operation without pressure.
3. Seal material FKM (Viton) is suitable for steam.
Notes:
1. Before laying the pipe, the pipe must be very clean, free from any pollutants or other things that should not exist.
2. In order to extend the service life of the product, y-type filter should be installed at the front end of the solenoid valve.
3. The temperature of steam shall not exceed 185℃.
4. AC voltage tolerance: ± 10%; DC voltage tolerance: ± 1%.
5. Horizontal installation; Vertical installation is not recommended.
Technical parameters of UNI-D Type US-8 / UD-8 / 2W025-08 Brass Solenoid Valve:
Model | Pipe size | CV | Orifice size | Fluid temperature | Operating pressure kgf/cm² (bar) | Vaccum (Torr) | ||||
Water | Air | Steam | Light oil | Gas | ||||||
UD-6 | 1/8'' | 0.23 | 2.5mm |
-5°C to +80°C |
0-7 | 0-7 | 0-7 | 0-7 | 0-10-3 | |
UD-8 | 1/4'' | 0-7 | 0-7 | 0-7 | 0-7 | 0-10-3 | ||||
US-6 | 1/8'' |
-5°C to +185°C |
0-7 | 0-7 | ||||||
US-8 | 1/4'' | 0-7 | 0-7 |
Main material of UNI-D Type US-8 / UD-8 / 2W025-08 1/4'' Inch Solenoid Valve:
Parts | Coil | Tube | Spring | Core | Plug | O-ring | Valve body |
Material |
Copper DIN43650A Best Nr.0200 Coil |
Stainless steel | Stainless steel | Stainless steel | FKM | FKM | Forged brass |
Main dimension of UNI-D Type US-8 / UD-8 / 2W025-08 Electromagnetic Valve AC220V:
Deconstruction diagram of US-8 / UD-8 / 2W025-08 UNI-D Type 2 Way Electromagnetic Valve:
Details enlargements of UNI-D Type US-8 / UD-8 / 2W025-08 2/2 NC Solenoid Valve:
Other connection type (flying wire leads, connector) for your reference:
More display about UNI-D Type US-8 / UD-8 / 2W025-08 Solenoid Valve in below Youtube Video:
The installation and use of UNI-D Type US-8 / UD-8 / 2W025-08 Solenoid Valve:
1. Please refer to the instruction manual of the product before installation to see if it meets your requirements.
2. The pipeline should be cleaned before use. If the medium is not clean, a filter should be installed to prevent impurities from obstructing the normal operation of the solenoid valve.
3. The solenoid valve is generally one-way work, can not be reversed, the arrow on the valve is the direction of movement of the pipeline fluid, must be consistent.
4. The solenoid valve is installed in the general valve body level, the coil is vertically upward, some products can be installed arbitrarily, but it is best to be vertical when conditions permit, to increase the service life.
5. When the solenoid valve is working again in the icing site, it should be heat treated or set with insulation measures.
6. After the electromagnetic coil lead wire (connector) is connected, it should be confirmed whether it is firm or not. The contact of the electrical component should not be shaken. Looseness will cause the solenoid valve to not work.
7. The solenoid valve for continuous production is preferably bypassed for easy maintenance and does not affect production.
8. The solenoid valve after long-term deactivation should be used after clearing the condensate; when removing and washing, the parts should be placed in order and then restored.
9. If you have any questions, please contact us and we will serve you wholeheartedly.
Welcome to your any question and inquiry!
Contact Person: Mr. Brandon Bao
Tel: 86-13454729544
Fax: 86-574-83879820
3'' DMF-Z-76S BFEC Diaphragm Pulse Jet Solenoid Valve For Bag Filter
CA25DD Goyen Type DD Series Pulse Jet Diaphragm Valve For Dust Collector
1'' SCG353A044 ASCO Type Diaphragm Pulse Jet Valve For Dust Removal
EVR 3 NC 032F8107 1/4'' Danfoss Type Refrigeration Solenoid Valve 220VAC
1028/3 Castel Type 3/8'' Refrigeration Solenoid Valve HM2 220VAC 230VAC
EVRA 40 EN-JS1025 Danfoss Type Ammonia Solenoid Valve 042H1128 042H1132
C113443 C113444 Diaphragm For ASCO Pulse Valve SCG353A043 SCG353A044
Diaphragm For BFEC Pulse Valve 1.5'' DMF-Z-40S DMF-ZM-40S DMF-Y-40S
K7600 K7601 Diaphragm Kit For Goyen Pulse Solenoid Valve CA76T CA76MM