Place of Origin: | China |
Brand Name: | Brando |
Certification: | CE |
Model Number: | SUW-40 |
Minimum Order Quantity: | 1 pc |
---|---|
Price: | $4 to $ 10 per pc |
Packaging Details: | Internal boxes, Cartons, Pallet |
Delivery Time: | 4-7 days |
Payment Terms: | L/C, T/T, PayPal, Western Union, MoneyGram |
Supply Ability: | 150000 pcs per month |
Name: | 2S400/40 / SUW-40 Solenoid Diaphragm Valve | Pipe Size: | 1-1/2'' |
---|---|---|---|
Connection Type: | Female Thread | Body Material: | 304 Stainless Steel |
Seal Material: | NBR (Standard), Viton (Available) | Operation: | Direct Lifting Diaphragm |
Function: | 2 Way Normally Closed (NC) | Voltages: | 24VDC, 110VAC, 220VAC |
Temperature Range: | -5 ℃ To +80 ℃ | Pressure Range: | 0 To 5 Bar (Water & Oil), 0 To 7 Bar (Air) |
Highlight: | Stainless Steel 304 Solenoid Valve,2 Way SS Solenoid Valve,Water Treatment Solenoid Valve |
NBR VITON Seal Normally Closed 1 1/2'' SUW-40 2S400-40 Uni-D Type Solenoid Diaphragm Valve 24V DC 220V AC
2S, SUS & SUW series stainless steel solenoid valves are devices that regulate fluid or air flow. Due to their durability and reliability, these devices are ideal for various industrial applications. They are used in the control of water, air, inert gases, steam, and of fluids in general that have different levels of aggressiveness. They are employed in various sectors, for both domestic and industrial use and are used for household appliances and coffee machines, drinks machines, industrial washing machines, autoclaves/sterilizers, irrigation systems and fire suppression, dental equipment, steam boilers and industrial applications.
YouTube video of 1 1/2'' 2S400-40 SUW-40 Uni-D Type Semi-direct Diaphragm Valve:
Main dimension of 1 1/2 Inch 2S400-40 SUW-40 Uni-D Type Solenoid Diaphragm Valve:
Details display of 2S400-40 SUW-40 Direct Lifting Diaphragm Water Solenoid Valve:
Specifications of 2S, SUS & SUW Series UNI-D Type Normally Closed Solenoid Valve:
Brando No | 2S025-06 | 2S025-08 | 2S040-10 | 2S160-10 | 2S160-15 | 2S200-20 | 2S250-25 | 2S350-35 | 2S400-40 | 2S500-50 |
Ref. No | SUS-6 | SUS-8 | SUS-10 | SUW-10 | SUW-15 | SUW-20 | SUW-25 | SUW-35 | SUW-40 | SUW-50 |
Working medium | Air, Inert Gas, Liquid, Vacuum | |||||||||
Valve type | 2 way, normally closed (NC) | |||||||||
Body material | Stainless steel 304 | |||||||||
Wetted Surface |
Valve Body: Stainless Steel Seals: NBR (Buna); Option: Viton (FKM) Armature Assembly: Stainless Steel |
|||||||||
Operation | Direct Lift Diaphragm, Uni-Directional, Zero Differential | |||||||||
Port size | 1/8'' | 1/4'' | 3/8'' | 3/8'' | 1/2'' | 3/4'' | 1'' | 1 1/4'' | 1 1/2'' | 2'' |
Operating pressure | 0 to 1.0mpa | |||||||||
Operating temperature | Media: -5 to 80°C (NBR Seal), -5 to 120°C (Viton Seal); Ambient: -5 to 45°C | |||||||||
Fluid viscosity | Below 20cst |
Common use for Irrigation, Fountains, Solar Heating, Automotive, Beer Brewing, Hydroponics, HVAC, and Plumbing:
Troubleshooting of common problems in solenoid valve:
Problem 1: The Valve makes noise
Reason 1: AC coils may have a slight hum do to cycle cycling. If top nut is lose, tightening it may reduce the noise.
Reason 2: Dirt or wear in the armature may cause a humming noise. Clean Armature tube.
Reasoon 3: LOUD BUZZING. If your solenoid valve is buzzing loudly immediately disconnect the valve. This may be caused by incorrect voltage or power supply and can cause serious bodily harm or system damage if not corrected.
Problem 2: The valve gets extremley hot or emits smoke.
Reason 1: The solenoid valve will become warm or uncomfortably hot to the touch. This is typically normal as it is dissipating heat.
Reason 2: If your solenoid valve is extremely hot or emitting smoke immediately disconnect the valve. This may be caused by incorrect voltage or power supply and can cause serious bodily harm or system damage if not corrected.
Problem 3: Nothing happens when I connect power
Reason 1: Make sure there is a proper electrical connection (voltage, current, frequency). Use a multimeter to test all components.
Reason 2: The coil is disconnected or burned out. Check your wiring to the coil and confirm the valve is receiving the correct specifications. OHMs can be checked to determine if the coil has burned out.
Focus on your demands, Offer you best solution:
√ Contact us if some points you have doubt
√ Contact us if somewhere need to change
√ Contact us if not the one you are looking for
√ Contact us if you are doing designing
Welcome to your any question and inquiry!
Contact Person: Mr. Brandon Bao
Tel: 86-13454729544
Fax: 86-574-83879820
3'' DMF-Z-76S BFEC Diaphragm Pulse Jet Solenoid Valve For Bag Filter
CA25DD Goyen Type DD Series Pulse Jet Diaphragm Valve For Dust Collector
1'' SCG353A044 ASCO Type Diaphragm Pulse Jet Valve For Dust Removal
EVR 3 NC 032F8107 1/4'' Danfoss Type Refrigeration Solenoid Valve 220VAC
1028/3 Castel Type 3/8'' Refrigeration Solenoid Valve HM2 220VAC 230VAC
EVRA 40 EN-JS1025 Danfoss Type Ammonia Solenoid Valve 042H1128 042H1132
C113443 C113444 Diaphragm For ASCO Pulse Valve SCG353A043 SCG353A044
Diaphragm For BFEC Pulse Valve 1.5'' DMF-Z-40S DMF-ZM-40S DMF-Y-40S
K7600 K7601 Diaphragm Kit For Goyen Pulse Solenoid Valve CA76T CA76MM