Place of Origin: | China |
Brand Name: | Brando |
Certification: | CE |
Model Number: | DMF-Z-62S |
Minimum Order Quantity: | 1 pc |
---|---|
Price: | Negotiation |
Packaging Details: | inner boxes,cartons,pallets |
Delivery Time: | Negotiation |
Payment Terms: | L/C, T/T, Western Union |
Supply Ability: | 100000pcs per month |
Port Size: | 2-1/2 Inch | Nominal Diametrer(mm): | Φ62 |
---|---|---|---|
Number Of Diaphragm: | 2 | Power: | Solenoid |
Structure: | Diaphragm | Blowing Area: | 27 - 38㎡ |
Working Temperature: | -25℃ To +80℃ | Pressure: | 0.1- 0.8MPa |
Highlight: | BFEC Pulse Valve,BFEC Diaphragm Valve,BFEC Solenoid Valve |
BFEC Type Right Angle 2-1/2'' Aluminum Alloy Pneumatic Pulse Valve For Dust Collector DMF-Z-62S
This valve below is DMF-Z-62S right angle type solenoid pulse jet valve with die-casting aluminum alloy body. It simplifies the connection between gas bag and blowing tube of a dust collector. It can provide stronger airflow and meet dust removing requirements.
The high-pressure gas enters from the air inlet , enters the lower air chamber.
1. When the pulse valve is not energized, the gas enters the decompression chamber through the impulse valve and the orifice in the constant pressure pipeline on the upper and lower shells. The valve core blocks the pressure relief hole under the action of the spring. The gas will not be discharged, so that the pressure in the decompression chamber and the lower air chamber are consistent. Under the action of the spring, the diaphragm will block the injection port, and the gas will not burst out.
2. When the pulse valve is energized, the valve core is lifted upward by the electromagnetic force, the pressure relief hole is opened, and the gas is ejected. Due to the role of the orifice of the constant pressure pipe, the outflow speed of the pressure relief hole is greater than that of the decompression chamber. The inflow speed of the pressure pipe gas makes the pressure in the decompression chamber lower than the pressure in the lower chamber. The gas in the lower chamber lifts up the diaphragm, opens the injection port, and performs gas injection.
Specification Of DMF-Z-62S Electromagnetic Pulse Jet Valve:
Model Number | DMF-Z-62S |
Port Size | G2-1/2'' |
Number of Diaphragm | 2 |
KV/CV | 129.26/150.85 |
Media | Clean Air |
Voltage | AC220V, C110V, C24V, DC24V |
Connection Type | Thread |
Relative Humidity of Air | ≤85% |
Seal Material | NBR, HNBR, FKM, EPDM, Silicone, All Available |
Body Material | Aluminum Alloy |
Overall Diemension
Deconstruction Diagram
Flow Direction Of DMF-Z-62S:
FAQ:
1.During installation and commissioning
1). The valve cannot be opened, but the pilot is operating. → Check if the airbag pressure is too low → Exclude air leaks.
2). Some valves are not working, others are normal.→Check the valve's wiring link and solenoid coil. → Replacement of accessories.
3). The valve cannot be closed and there is a leak, pressure cannot be established. → The inlet of the valve is installed opposite the injection port. → reassemble
4). The valve cannot be closed and there is a leak. → Impurities are adsorbed on the diaphragm, and the iron core is stuck. →Clean the diaphragm, check whether the diaphragm is complete, check the iron core, and replace the parts in time.
2.During use
1). Valve closes slowly. → Diaphragm orifice blocked. →Dredge orifice.
2). Some valves leak, the diaphragm does not close,normally opened. → Impurities are adsorbed on the diaphragm, the pilot is damaged, and the iron core is stuck. → Clean the diaphragm, check whether the diaphragm is complete, check the iron core, and replace the parts in time.
3). The coil is hot and burned. → Power on for a long time. → Check the working condition of the control system.
4). There is voltage but the valve is not working. → Damaged diaphragm or blocked orifice. → Replace parts in time.
5). Low ambient temperature, the valve is leaking or cannot be opened. → Ambient temperature is too low, there is icing in the valve. → Note the valve operating temperature range.
Welcome to your any question and inquiry!
Contact Person: Mr. Brandon Bao
Tel: 86-13454729544
Fax: 86-574-83879820
3'' DMF-Z-76S BFEC Diaphragm Pulse Jet Solenoid Valve For Bag Filter
CA25DD Goyen Type DD Series Pulse Jet Diaphragm Valve For Dust Collector
1'' SCG353A044 ASCO Type Diaphragm Pulse Jet Valve For Dust Removal
EVR 3 NC 032F8107 1/4'' Danfoss Type Refrigeration Solenoid Valve 220VAC
1028/3 Castel Type 3/8'' Refrigeration Solenoid Valve HM2 220VAC 230VAC
EVRA 40 EN-JS1025 Danfoss Type Ammonia Solenoid Valve 042H1128 042H1132
C113443 C113444 Diaphragm For ASCO Pulse Valve SCG353A043 SCG353A044
Diaphragm For BFEC Pulse Valve 1.5'' DMF-Z-40S DMF-ZM-40S DMF-Y-40S
K7600 K7601 Diaphragm Kit For Goyen Pulse Solenoid Valve CA76T CA76MM