Place of Origin: | CHINA |
Brand Name: | Brando |
Certification: | CE |
Model Number: | DMF-Y-50S |
Minimum Order Quantity: | one set |
---|---|
Price: | Negotiation |
Packaging Details: | Inner Box,Carton,Pallet |
Delivery Time: | Negotiation |
Payment Terms: | T/T, Western Union, L/C, MoneyGram, D/P, D/A |
Supply Ability: | 150000 pieces per month |
Port Size: | G 2'' Inch | Material: | Aluminum |
---|---|---|---|
Number Of Diaphragm: | 2 | Media: | Clean Air |
Application: | Dust Cleaner Equipment | Power: | Solenoid,Pneumatic |
Pressure: | 0.3MPa~0.6MPa | Structure: | Diaphragm |
Temperature Of Media: | -35℃~+45℃ | Voltage: | AC110V/AC220V/DC24V/12VDC |
Highlight: | pulse jet valves,solenoid pulse valve |
AC220V DC 24V 2'' Inch DN50 DMF-Y-50S Electromagnetic Pulse Control Valve For Dust Collector
Right-angle electromagnetic pulse valve, the Angle between the inlet and outlet is 90, suitable for the safety connection between the air bag and the dust blower. The airflow is unobstructed and can provide the required ash removal pulse.
Submersible electromagnetic pulse valve, which is directly installed on the air distributor box, has better flow characteristics, pressure loss has been reduced, suitable for the lower air pressure workplace.
Ningbo Brando Hardware Co.Ltd is a professional production of pulse valves, pulse valve diaphragm, pulse control instrument, and sales of various pneumatic components products, the factory specializes in the production of pulse valves, pulse valve diaphragm focus on quality, reasonable price.Pulse valve diaphragm manufacturing has reached 15 years, has been well received by domestic and foreign customers, in the spirit of mutual benefit, integrity and compliance with the business philosophy to create a win-win market with you.
Technical data chart of DMF Y series solenoid pulse valves in industrial filter use:
Model Numbers | DMF-Y-25 | DMF-Y-40S | DMF-Y-50S | DMF-Y-62S | DMF-Y-76S | DMF-Y-102S |
Port size |
G1'' | G1 1/2'' |
G2'' |
G2 1/2'' |
G3'' |
G4'' |
Membrane sizes
(φ66 smaller)
|
φ96 | φ112 | φ160 | φ188 | φ202 | φ255 |
CV values | 30.53 | 53.47 | 71.47 | 150.85 | 186.66 | 313.09 |
Blowing area (m2) | 8-10 | 12-16 | 18-28 | 27-38 | 37-65' | 70-90 |
Weighgt (kg) | 0.75 | 1.2 | 2.35 | 3.2 | 4.05 | 6.65 |
Environment Temperature | -25℃-80℃ or customized | |||||
Relative Humidity | ≤85% | |||||
Working Medium | Clean Air | |||||
Protection class | IP 65 | |||||
Service life cycle | Over million times | |||||
Voltages | AC110V/AC220V/DC12V/DC24V/12VDC |
Overall dimension of DMF-Y-50S Pneuamtic Pulse Solenoid Valve Aluminum Body for Dust Collector:
Detail Images Of DMF Series Control Solenoid Valve:
Tips: All accessories can be sold separately as repair parts (Diaphragm, Solenoid Coil, Armature Assembly)
Youtube video of DMF Dust Collector Pulse Solenoid Valve
Working place view of DMF clean air solenoid pulse jet valve single diaphragm:
Common faults and repair methods of DMF membrane pulse solenoid valve:
1. The spring is damaged. The spring on the pulse valve spool is easily damaged. The appearance is that the pulse valve is deflated to the blow port for a long time. The treatment method is to replace the spring.
2. the valve core dirt, because the intake air is not clean, causing the fouling of the valve core, resulting in the appearance of long-term intake of the nozzle or the pulse valve does not work after the power, the treatment method is to clean the valve core.
3. the diaphragm is damaged, after long-term work, the diaphragm is easy to fatigue, oxidation, etc., resulting in the appearance of long-term deflation of the pressure relief port, the pulse valve does not work, the treatment is to replace the diaphragm.
4. The rubber pad is damaged. After the use time is long, the rubber pad on the pulse valve spool is easily damaged. The appearance is that the pulse valve is deflated to the blowing port for a long time. The treatment method is to replace the rubber pad.
5. The orifice is blocked or damaged. The intake air is not clean and the throttle hole is blocked. The appearance is that the pulse valve is deflated to the nozzle for a long time. The treatment method is to clean the orifice; the orifice is damaged or missing, and the orifice is made. Loss of interception, resulting in abnormal pressure relief, the appearance of the pulse valve after the power is activated, the pressure relief port deflation, but the pulse valve is not sprayed, the treatment is a replacement orifice.
Focus on your demands, Offer you best solution:
√ Contact us if some points you have doubt
√ Contact us if somewhere need to change
√ Contact us if not the one you are looking for
√ Contact us if you are doing designing
Welcome to your any question and inquiry!
Contact Person: Brandon Bao
Tel: 86-13454729544
Fax: 86-574-83879820
3'' DMF-Z-76S BFEC Diaphragm Pulse Jet Solenoid Valve For Bag Filter
CA25DD Goyen Type DD Series Pulse Jet Diaphragm Valve For Dust Collector
1'' SCG353A044 ASCO Type Diaphragm Pulse Jet Valve For Dust Removal
EVR 3 NC 032F8107 1/4'' Danfoss Type Refrigeration Solenoid Valve 220VAC
1028/3 Castel Type 3/8'' Refrigeration Solenoid Valve HM2 220VAC 230VAC
EVRA 40 EN-JS1025 Danfoss Type Ammonia Solenoid Valve 042H1128 042H1132
C113443 C113444 Diaphragm For ASCO Pulse Valve SCG353A043 SCG353A044
Diaphragm For BFEC Pulse Valve 1.5'' DMF-Z-40S DMF-ZM-40S DMF-Y-40S
K7600 K7601 Diaphragm Kit For Goyen Pulse Solenoid Valve CA76T CA76MM