Place of Origin: | China |
Brand Name: | Brando |
Certification: | CE |
Model Number: | BPV02-F |
Minimum Order Quantity: | 1pc |
---|---|
Packaging Details: | Inner boxes, Carton, Pallet |
Delivery Time: | 4-8 days |
Payment Terms: | L/C, T/T, Western Union, MoneyGram |
Supply Ability: | 100000 pcs per month |
Application: | Reverse Osmosis, Process Water, RO Water System, Water Purifier, Pure Water, Water Dispenser | Temperature: | -10℃~+80℃ |
---|---|---|---|
Power: | Solenoid | Media: | Water, Air, Oil |
Structure: | Plunger | Operation: | Direct Acting |
Seal Material: | NBR, FKM, EPDM | Voltage: | DC12V DC24V AC24V AC120V AC240V |
Outer Diameter: | Φ6.35mm | Body Material: | Nylon, PP, POM |
Highlight: | Push Fitting RO Solenoid Valve,Reverse Osmosis System RO Solenoid Valve,Water Purifier Solenoid Valve |
RO SV Push Fitting RO Solenoid Valve For Reverse Osmosis System
BPV02-F is a reverse osmosis system solenoid valve with fast connection, Outer Diameter Φ6.35mm. The main function of the water inlet solenoid valve in the pure water machine is to control the water inlet. When working, the water inlet solenoid valve is opened to allow water to pass; when stops working, the water inlet solenoid valve is closed to directly cut off the water source.
The water inlet solenoid valve is generally Direct Acting.
working principle: when the power is turned on, the electromagnetic force first opens the pilot hole, and the pressure in the upper chamber drops rapidly. A high pressure difference is formed around the closing part. The fluid pressure pushes the closing part upward and the valve opens; when the power is off, the spring force closes the pilot hole, and the inlet pressure quickly passes through the chamber through the bypass hole.
The upper limit of the fluid pressure range is high, and it can be installed arbitrarily but must meet the fluid pressure difference conditions. A pressure difference between lower and upper is formed around, and the fluid pressure pushes the closing member to move downward to close the valve.
Technical data:
Characteristic | 1)Direct acting,0 rated bar pressure.low power 2)compact design to save the space |
Medium | Air,water,steam,oil,etc. |
Temperature |
NBR: -10°C to 80 °C EPDM: -10°C to 120 °C FKM:-10°C to 150 °C |
Pressure | 0-1.6Mpa |
Port Size | 1/4'' |
Port Thread | G, NPT |
Orifice | 2.5mm |
Voltage |
DC-12V,24V AC-24V,120V,110V,220V/50HZ |
Voltage Range | ±10% |
Material |
Body-Nylon,PP,POM Amature tube-stainless steel 304 Plunger-stainless steel430F Stop-stainless steel 430F Springs-SS304 Shading rings- stainless steel 304 |
Main Dimension of RO Solenoid Water Valve:
Brando Factory Production of Solenoid Valves:
More Plastic Reverse Osmosis Solenoid Valve(RO SV):
Reverse Osmosis systems
A simple reverse osmosis system consists of a high-pressure pump which increases the pressure of the feed water with salts, ions or impurities. This forces the water across the semi permeable RO (Reverse Osmosis) membrane, leaving behind all the dissolved salts. The required pressure is directly proportional to the salt concentration of the inlet water. The higher the concentration, the higher pressure is required to overcome the osmotic pressure.
The RO membrane lets the cleaner water through and this is called permeate water. The salts and other contaminants which are stopped by the membrane come out as a reject stream. This can be drained out or recycled if possible through the RO system to save water.
The RO systems remove up to 99% of dissolved salts (ions), particles, pathogens and bacteria from feed water.
Focus on your demands, Offer you best solution:
√ Contact us if some points you have doubt
√ Contact us if somewhere need to change
√ Contact us if not the one you are looking for
√ Contact us if you are doing designing
Welcome to your any question and inquiry!
Contact Person: Mr. Brandon Bao
Tel: 86-13454729544
Fax: 86-574-83879820
3'' DMF-Z-76S BFEC Diaphragm Pulse Jet Solenoid Valve For Bag Filter
CA25DD Goyen Type DD Series Pulse Jet Diaphragm Valve For Dust Collector
1'' SCG353A044 ASCO Type Diaphragm Pulse Jet Valve For Dust Removal
EVR 3 NC 032F8107 1/4'' Danfoss Type Refrigeration Solenoid Valve 220VAC
1028/3 Castel Type 3/8'' Refrigeration Solenoid Valve HM2 220VAC 230VAC
EVRA 40 EN-JS1025 Danfoss Type Ammonia Solenoid Valve 042H1128 042H1132
C113443 C113444 Diaphragm For ASCO Pulse Valve SCG353A043 SCG353A044
Diaphragm For BFEC Pulse Valve 1.5'' DMF-Z-40S DMF-ZM-40S DMF-Y-40S
K7600 K7601 Diaphragm Kit For Goyen Pulse Solenoid Valve CA76T CA76MM