CA35T 1-1/4'' Right Angle Thread Integral Pilot Dust Collector Valve
Pulse jet valves common fault handling methods:
The air bag capacity is too small, or the air supply pipe of the air bag is too small, and the air supply after the injection is insufficient, the pulse solenoid valve cannot be closed normally (closed), and the diaphragm oscillates (resonance phenomenon).
Treatment: connect several small air bags into a large-capacity gas storage circuit; place the gas-regulated gas tank as close as possible to the dust collector air bag and add the air-filled gas supply pipe.
The pulse width of the pulse solenoid valve is too long, and the coil is energized for a long time, which causes electromagnetic memory. The push rod in the electromagnetic pilot valve cannot be reset, the diaphragm cannot be closed, the residual pressure in the air bag is too low, and the air supply is insufficient. .
Solution: Replace the pulse solenoid push rod and replace the upper cover of the small diaphragm if necessary.
Technical Data of Goyen Pulse Jet Valve:
Model No
|
CA15T
|
CA20T
|
CA25T
|
CA35T
|
CA45T
|
CA50T
|
CA62T
|
CA76T
|
Nonimal size
|
φ15
|
φ20
|
φ25
|
φ35
|
φ45
|
φ50
|
φ62
|
φ76
|
Port Size
|
G1/2''
|
G3/4''
|
G1''
|
G1 1/4''
|
G1 1/2''
|
G2''
|
G2 1/2''
|
G3''
|
Working pressure
|
0.3-0.8MPa
|
|||||||
Temp. range
|
-5℃ - 55℃
|
|||||||
Relative humidity
|
≤85%
|
|||||||
Working
medium
|
Compressed clean air
|
|||||||
Service life
|
Over 1000000 times
|
|||||||
Voltage
|
DC24V, AC24V, AC110V, AC220V
|
Main Dimension:
CA RCA Series Pulse Jet Valve For Dust Collector System:
Decentralized mechanical dust removal system
Decentralized mechanical dust removal system In a workshop, a dust removal system that only connects 1-2 extraction points is called a decentralized mechanical dust removal system. In the powder processing workshop, when the local exhaust hoods are far apart or the dust-distributing equipments are not working at the same time and the materials processed by the dust-discharging equipment are different, it is reasonable to set up a decentralized dust-removing system. Simple, able to accommodate production conditions, dust removal effect is more reliable, and can be directly operated by production operators. However, dust collection and recycling by dust removal equipment is not as convenient and easy as centralized dust removal system.
Focus on your demands, Offer you best solution:
√ Contact us if some points you have doubt
√ Contact us if somewhere need to change
√ Contact us if not the one you are looking for
√ Contact us if you are doing designing
Welcome to your any question and inquiry!
Contact Person: Brandon Bao
Tel: 86-13454729544
Fax: 86-574-83879820
3'' DMF-Z-76S BFEC Diaphragm Pulse Jet Solenoid Valve For Bag Filter
CA25DD Goyen Type DD Series Pulse Jet Diaphragm Valve For Dust Collector
1'' SCG353A044 ASCO Type Diaphragm Pulse Jet Valve For Dust Removal
EVR 3 NC 032F8107 1/4'' Danfoss Type Refrigeration Solenoid Valve 220VAC
1028/3 Castel Type 3/8'' Refrigeration Solenoid Valve HM2 220VAC 230VAC
EVRA 40 EN-JS1025 Danfoss Type Ammonia Solenoid Valve 042H1128 042H1132
C113443 C113444 Diaphragm For ASCO Pulse Valve SCG353A043 SCG353A044
Diaphragm For BFEC Pulse Valve 1.5'' DMF-Z-40S DMF-ZM-40S DMF-Y-40S
K7600 K7601 Diaphragm Kit For Goyen Pulse Solenoid Valve CA76T CA76MM