Place of Origin: | China |
Brand Name: | Brando |
Certification: | CE |
Model Number: | UW-50 |
Minimum Order Quantity: | 1 piece |
---|---|
Price: | $5 to $15 per pc |
Packaging Details: | Individual box, Carton, Pallet |
Delivery Time: | 5-9 days |
Payment Terms: | L/C, T/T, Western Union, MoneyGram |
Supply Ability: | 100000 pcs per month |
Product Name: | UW-50 Uni-D Type Electric Solenoid Valve | Function: | 2/2 Way, Normally Closed (NC) |
---|---|---|---|
Operation: | Semi-direct Operated | Port Size: | 2'' |
Connection Form: | Female Thread | Voltages: | AC220V, AC110V, DC12V, DC24V |
Valve Body: | Brass | Diaphragm: | Nitrile(Standard), Viton(Optional) |
Working Temperature: | -5℃ - +80°C (NBR Seals), -5℃ - +120°C (Viton Seals) | Working Pressure: | 0 - 7 Bar (Air, Water), 0 - 5 Bar (Oil) |
Highlight: | 2" 2W500-50 Electric Solenoid Valve,NBR Diaphragm Electric Solenoid Valve,Uni-D Type UW-50 |
2" 2W500-50 NBR Diaphragm Brass Electric Solenoid Valve AC110V DC24V
These UW-50 / 2W500-50 electric solenoid valves feature a normally closed valve configuration. These brass solenoid valves are rated for indoor or outdoor work environments. Models are available for dispensing, collating, gas shutoff, vacuum holding, and tank draining. The port size is DN50 2'', and the orifice size is 50mm, so these high-flow valves are ideal for liquid, corrosive, and air/inert gas service in applications such as car washes, air compressors, pumps, laundry equipment, and industrial water control. Solenoid valves from Brando contain small electromagnetic coils that can control backflow in plumbing systems, mix and distribute liquids during processing, and act as shutoffs or release valves in chemical transfer and storage applications. Whether it's a simple two-way solenoid valve for a car wash, or a four-way solenoid valve for chemical manufacturing, Brando can supply it.
YouTube video of UW-50 UNi-D Type Solenoid Valve Normally Closed:
Overall dimension of G2'' 2W500-50 2/2 Way NC Electric Solenoid Valve:
Details display of 2 Way Semi-direct Operated NBR Diaphragm Valve:
Technical parameters of 2W, UD & UW Series Normally Closed Solenoid Valve:
Brando number | 2W025-06 | 2W025-08 | 2W040-10 | 2W160-10 | 2W160-15 | 2W200-20 | 2W250-25 | 2W350-35 | 2W400-40 | 2W500-50 |
Reference number | UD-6 | UD-8 | UD-10 | UW-10 | UW-15 | UW-20 | UW-25 | UW-35 | UW-40 | UW-50 |
Working medium | Air, Inert Gas, Liquid, Vacuum | |||||||||
Valve type | 2/2 way, normally closed (NC) | |||||||||
Main materials |
Body: Brass Seals: NBR (Buna); Option: Viton (FKM) Armature Assembly: Stainless Steel |
|||||||||
Operation | Direct Acting, Uni-Directional, Zero Differential | |||||||||
Pipe size | 1/8'' | 1/4'' | 3/8'' | 3/8'' | 1/2'' | 3/4'' | 1'' | 1 1/4'' | 1 1/2'' | 2'' |
Working pressure | 0 to 101 PSI / 0-7 Bar (for Air, Water); 0 to 72 PSI / 0-5 Bar (for Oil) | |||||||||
Working temperature | Media: -5 to 80°C (NBR Seals), -5 to 120°C (VITON Seals); Ambient: -5 to 45°C | |||||||||
Fluid viscosity | Below 20cst |
Application examples of Water Gas Oil Fuel Control Brass Solenoid Valve:
Production process display of 2-Way Brass Body Diaphragm Solenoid Valve:
Product features of 2W500-50 / UW-50 solenoid valve:
1.The semi-direct diaphragm operated structure has no pressure to start, and expands its application field.
2.The use of flat diaphragm structure is reliable and enhances the service life of the product.
Installation and use of 2W / UW series solenoid valves:
1.The pipes should be rinsed before use, and filters should be installed if the media are not clean, so as to prevent impurities from hindering the normal operation of the solenoid valves.
2.Solenoid valves are usually unidirectional and can not be reversed. The arrow on the valve is the movement direction of the pipeline fluid and must be kept consistent.
3.Solenoid valve installed in general body level, the coil vertical upward, some products can be installed at any time, but when conditions permit, it is best to vertical, in order to increase the service life.
4.Solenoid valves should be heat-treated or set up insulation measures when working in icing places.
5.After the connection of the solenoid lead wire (connector) is properly connected, it should be confirmed whether it is firm, and the contact points of the electrical components should not be jitters. Loosening will cause the solenoid valve not to work.
6.Continuous production of solenoid valve, it is best to use bypass, easy to repair, do not affect production.
7.After a long time, the solenoid valve should be cleared after setting up the condensate. The parts should be put in order and restored to original condition.
Focus on your demands, Offer you best solution:
√ Contact us if some points you have doubt
√ Contact us if somewhere need to change
√ Contact us if not the one you are looking for
√ Contact us if you are doing designing
Welcome to your any question and inquiry!
Contact Person: Mr. Brandon Bao
Tel: 86-13454729544
Fax: 86-574-83879820
3'' DMF-Z-76S BFEC Diaphragm Pulse Jet Solenoid Valve For Bag Filter
CA25DD Goyen Type DD Series Pulse Jet Diaphragm Valve For Dust Collector
1'' SCG353A044 ASCO Type Diaphragm Pulse Jet Valve For Dust Removal
EVR 3 NC 032F8107 1/4'' Danfoss Type Refrigeration Solenoid Valve 220VAC
1028/3 Castel Type 3/8'' Refrigeration Solenoid Valve HM2 220VAC 230VAC
EVRA 40 EN-JS1025 Danfoss Type Ammonia Solenoid Valve 042H1128 042H1132
C113443 C113444 Diaphragm For ASCO Pulse Valve SCG353A043 SCG353A044
Diaphragm For BFEC Pulse Valve 1.5'' DMF-Z-40S DMF-ZM-40S DMF-Y-40S
K7600 K7601 Diaphragm Kit For Goyen Pulse Solenoid Valve CA76T CA76MM