Male Screw Thread High Quality Promised Solenoid Stem/Rubber Band And Internal Spring Core
Know more specification of BAPC214338568
Brand | BRANDO |
NO. | BAPC214338568 |
Voltage | AC/DC |
Tube OD | 14.3mm |
Tube height | 38.5mm |
Item weight | 75g |
Movable core height | 34.0mm |
Depth | 34.5mm |
Armature height | 60.8mm |
Material | Stainless steel |
Type | Two way two way normaly closed solenoid stem |
Seat | Pentagon thread seat |
Seal | NBR |
Standard or no | Standard |
Connection | Male thread |
Spring | Internal compress spring |
MOre detail information and other product specification are in our web |
Application of solenoid stem
This item Mainly uses for pneumatic series such as pneumatic solenoid valve and so on
Other type of solenoid stem/application
For instance
1.Dental equipment
2.Dust collector valve
3.Automatic vending machine
4.Pulse device
5.Pneumatic equipment
6.Auto drain industry
7.Air suspension
8.Refrigeration device
9.Hyraulic industry
10.Life water and industry water supply
11.Air condition device/Air suspension valve
12.Pipe switch
13.Evr solenoid valve
14.Forged brass solenoid valve
Solenoid stem seal choose
1.NBR
2.Viton
3.PTFE
4.EPDM
ETC
Key points of construction and installation(after assembling)
1.The installation position and height of the valve must conform to the design requirements of the mouth direction, and the connection should be firm and tight.
2.The valve must be inspected before installation. The nameplate of the valve should conform to the current national standard GB12220 "General Valve Mark".
Solenoid valve Installation notes(After assembling)
1.installation should pay attention to the arrow on the valve body should be consistent with the media flow direction. Do not install in places where there is direct drip or splash. Solenoid valve should be installed vertically.
2.solenoid valve should be guaranteed to operate normally within the 15%-10% fluctuation range of the supply voltage.
3.After installing the solenoid valve, there should be no reverse pressure difference in the pipeline. And it needs to be energized several times to make it suitable for temperature before it can be put into operation. 4.Solenoid valve should be thoroughly cleaned before installation. The medium should be free of impurities. Filter before valve. 5, when the solenoid valve malfunctions or cleaning, to ensure that the system continues to operate, it should install at bypass devices.
Overall Dimension of pneumatic solenoid valve(This item mainly used for pneumatic solenoid valve)
Contact Person: Brandon Bao
Tel: 86-13454729544
Fax: 86-574-83879820
3'' DMF-Z-76S BFEC Diaphragm Pulse Jet Solenoid Valve For Bag Filter
CA25DD Goyen Type DD Series Pulse Jet Diaphragm Valve For Dust Collector
1'' SCG353A044 ASCO Type Diaphragm Pulse Jet Valve For Dust Removal
EVR 3 NC 032F8107 1/4'' Danfoss Type Refrigeration Solenoid Valve 220VAC
1028/3 Castel Type 3/8'' Refrigeration Solenoid Valve HM2 220VAC 230VAC
EVRA 40 EN-JS1025 Danfoss Type Ammonia Solenoid Valve 042H1128 042H1132
C113443 C113444 Diaphragm For ASCO Pulse Valve SCG353A043 SCG353A044
Diaphragm For BFEC Pulse Valve 1.5'' DMF-Z-40S DMF-ZM-40S DMF-Y-40S
K7600 K7601 Diaphragm Kit For Goyen Pulse Solenoid Valve CA76T CA76MM